<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="1.3" article-type="research-article" xml:lang="en"><front><journal-meta><journal-id journal-id-type="issn">2357-0857</journal-id><journal-title-group><journal-title>Environmental Science &amp; Sustainable Development</journal-title><abbrev-journal-title>ESSD</abbrev-journal-title></journal-title-group><issn pub-type="epub">2357-0857</issn><issn pub-type="ppub">2357-0849</issn><publisher><publisher-name>IEREK Press</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21625/essd.v4i1.487</article-id><article-categories/><title-group><article-title>Selecting Ventilation Fan Capacity for University Classroom Based on Empirical Data</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Taemthong</surname><given-names>Wannawit</given-names></name><xref ref-type="aff" rid="AFF-1"/></contrib></contrib-group><contrib-group><contrib contrib-type="editor"><name><surname>Press</surname><given-names>IEREK</given-names></name><address><country>Italy</country></address></contrib></contrib-group><aff id="AFF-1">Associate Professor, King Mongkut’s University of Technology North Bangkok, Bangkok, Thailand</aff><pub-date date-type="pub" iso-8601-date="2019-3-30" publication-format="electronic"><day>30</day><month>3</month><year>2019</year></pub-date><pub-date date-type="collection" iso-8601-date="2019-3-30" publication-format="electronic"><day>30</day><month>3</month><year>2019</year></pub-date><volume>4</volume><issue>1</issue><issue-title>Improving Sustainability Concept:  From Theories to Successful Practices (Special Issue)</issue-title><fpage>13</fpage><lpage>21</lpage><history><date date-type="received" iso-8601-date="2019-3-30"><day>30</day><month>3</month><year>2019</year></date></history><permissions><copyright-statement>Copyright (c) 2019 Wannawit Taemthong</copyright-statement><copyright-year>2019</copyright-year><copyright-holder>Wannawit Taemthong</copyright-holder><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/"><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/">https://creativecommons.org/licenses/by/4.0/</ali:license_ref><license-p>This work is licensed under a Creative Commons Attribution 4.0 International License.The Author shall grant to the Publisher and its agents the nonexclusive perpetual right and license to publish, archive, and make accessible the Work in whole or in part in all forms of media now or hereafter known under a Creative Commons Attribution 4.0 License or its equivalent, which, for the avoidance of doubt, allows others to copy, distribute, and transmit the Work under the following conditions:Attribution: other users must attribute the Work in the manner specified by the author as indicated on the journal Web site;With the understanding that the above condition can be waived with permission from the Author and that where the Work or any of its elements is in the public domain under applicable law, that status is in no way affected by the license.The Author is able to enter into separate, additional contractual arrangements for the nonexclusive distribution of the journal's published version of the Work (e.g., post it to an institutional repository or publish it in a book), as long as there is provided in the document an acknowledgement of its initial publication in this journal.Authors are permitted and encouraged to post online a pre-publication manuscript (but not the Publisher's final formatted PDF version of the Work) in institutional repositories or on their Websites prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (see The Effect of Open Access). Any such posting made before acceptance and publication of the Work shall be updated upon publication to include a reference to the Publisher-assigned DOI (Digital Object Identifier) and a link to the online abstract for the final published Work in the Journal.Upon Publisher's request, the Author agrees to furnish promptly to Publisher, at the Author's own expense, written evidence of the permissions, licenses, and consents for use of third-party material included within the Work, except as determined by Publisher to be covered by the principles of Fair Use.The Author represents and warrants that:The Work is the Author's original work;The Author has not transferred, and will not transfer, exclusive rights in the Work to any third party;The Work is not pending review or under consideration by another publisher;The Work has not previously been published;The Work contains no misrepresentation or infringement of the Work or property of other authors or third parties; andThe Work contains no libel, invasion of privacy, or other unlawful matter.The Author agrees to indemnify and hold Publisher harmless from Author's breach of the representations and warranties contained in Paragraph 7 above, as well as any claim or proceeding relating to Publisher's use and publication of any content contained in the Work, including third-party content.This work is licensed under a Creative Commons Attribution 4.0 International License.</license-p></license></permissions><self-uri xlink:href="https://press.ierek.com/index.php/ESSD/article/view/487" xlink:title="Selecting Ventilation Fan Capacity for University Classroom Based on Empirical Data">Selecting Ventilation Fan Capacity for University Classroom Based on Empirical Data</self-uri><abstract><p>This paper presents a guideline for selecting ventilation fan based on empirical data. The research project was undertaken in a university classroom of 64 square meters. In a two-hour experiment, carbon dioxide levels exceeded 1600 ppm when not using any ventilation system. Subsequently, the carbon dioxide levels increased approximately at a rate of 11.49 ppm per minute for 15 students sitting in the room. The carbon dioxide levels within the tested classroom exceeded 1000 ppm after the 42<sup>nd</sup> minute. When students left the room, CO<sub>2</sub> decreased approximately at a rate of 3.67 ppm per minute. Straight-line functions were used to model the increasing and decreasing behaviour of CO<sub>2</sub> concentration in the classroom. An example of how to select an appropriate ventilation fan capacity is shown as an approximation guideline.</p></abstract><kwd-group><kwd>Carbon dioxide</kwd><kwd>Classroom</kwd><kwd>Indoor air quality</kwd><kwd>Ventilation</kwd></kwd-group><custom-meta-group><custom-meta><meta-name>File created by JATS Editor</meta-name><meta-value><ext-link ext-link-type="uri" xlink:href="https://jatseditor.com" xlink:title="JATS Editor">JATS Editor</ext-link></meta-value></custom-meta><custom-meta><meta-name>issue-created-year</meta-name><meta-value>2019</meta-value></custom-meta></custom-meta-group></article-meta></front><body><sec><title>Introduction</title><p>Ventilation rates have significant impacts on building energy and indoor air quality <xref ref-type="bibr" rid="BIBR-20">(Persily, 2016)</xref>. Good indoor air quality promotes occupant health, comfort and workplace productivity <xref ref-type="bibr" rid="BIBR-7">(Cheong &amp; Chong, 2001)</xref>. Thermal com- fort in classrooms is an important requirement to promote students’ efficiency and reduce health symptoms <xref ref-type="bibr" rid="BIBR-25">(Stazi et al., 2017)</xref>. Indoor carbon dioxide concentrations can be used to measure building ventila- tion and indoor air quality <xref ref-type="bibr" rid="BIBR-21">(Persily &amp; Jonge, 2017)</xref>. As ventilation to supply fresh air in an air-conditioned office consumes a considerable portion of energy, while higher ventilation rates result in less dilution, high ventilation rates can have a huge impact on both energy costs and comfort <xref ref-type="bibr" rid="BIBR-29">(Wong &amp; Mui, 2008)</xref>, <xref ref-type="bibr" rid="BIBR-22">(Prill, 2000)</xref>. Higher indoor air quality initiatives result in a nonlinear increasing trend in annual thermal energy consumption <xref ref-type="bibr" rid="BIBR-29">(Wong &amp; Mui, 2008)</xref>. While low ventilation rates consume less energy, they may result in poor indoor air quality <xref ref-type="bibr" rid="BIBR-26">(Wang et al., 2016-06)</xref>. Indoor air quality is associated with student learning ability. Good air quality in classrooms enhance both children’ levels of concentration and teacher productivity <xref ref-type="bibr" rid="BIBR-8">(Clements-Croome et al., 2008)</xref>. High levels of CO<sub>2</sub> have been shown to have an effect on pupils’ learning ability <xref ref-type="bibr" rid="BIBR-11">(Griffiths &amp; Eftekhari, 2008)</xref>. Levels of carbon dioxide can increase by up to 4800 ppm during the first two hours of a classroom in a not well-ventilated classroom <xref ref-type="bibr" rid="BIBR-12">(Heudorf et al., 2009)</xref>. It has been established that mechanical ven- tilation systems are able to ensure the highest outdoor air supply rates in classrooms, independent of the season</p><p><xref ref-type="bibr" rid="BIBR-10">(Gao et al., 2014)</xref>. Installing an air exchange fan can reduce indoor CO<sub>2</sub> concentration by up to 10.4% <xref ref-type="bibr" rid="BIBR-14">(Kang et al., 2016)</xref>. Ventilation rates represent a critical parameter related to building energy bills and health and comfort of occupants <xref ref-type="bibr" rid="BIBR-5">(Batterman, 2017)</xref>. Poor ventilation potentially causes excessive humidity and the accumulation of gas or chemical exposure <xref ref-type="bibr" rid="BIBR-6">(J.A. et al., 2008)</xref>. <xref ref-type="bibr" rid="BIBR-27">(Wargocki &amp; Silva, 2015)</xref> studied impacts of manually window opening to reduce CO<sub>2</sub> level in school classroom. CO<sub>2</sub> sensors were provided as visual indicator in classrooms for teachers and students to react by opening windows. They found that energy usage increases in winter and cooling requirements reduces in summer due to such operation. Overall indoor air pollution exposures attribute to their health since most Europeans spend more than 90% of their time indoors <xref ref-type="bibr" rid="BIBR-1">(Arvanitis et al., 2010)</xref>. People spend most of their time in confined spaces and thus are exposed to high extent to chemicals accumulated indoor <xref ref-type="bibr" rid="BIBR-15">(Kotzias &amp; Pilidis, 2017)</xref>. Indoor air pollution has a high correlation to outdoor air source <xref ref-type="bibr" rid="BIBR-23">(Sabaziotis et al., 2017)</xref>. Strong emission sources affect indoor environment in buildings <xref ref-type="bibr" rid="BIBR-23">(Sabaziotis et al., 2017)</xref>. In order to design and manage ap- propriate ventilation systems, the effects of increasing and decreasing rates of CO<sub>2</sub> need to be studied. It is useful to know the carbon dioxide generation rates of students in a classroom. <xref ref-type="bibr" rid="BIBR-21">(Persily &amp; Jonge, 2017)</xref> studied CO<sub>2</sub> generation rates for building occupants based on human metabolism and exercise physiology. Several methods can be used to estimate and model CO<sub>2</sub>. <xref ref-type="bibr" rid="BIBR-16">(Lawrence &amp; Braun, 2007)</xref> suggested a methodology for estimating CO<sub>2</sub> using field measurements and developed a CO<sub>2</sub> schedule to manage demand-controlled ventilation in small commercial buildings. <xref ref-type="bibr" rid="BIBR-17">(Lu et al., 2010)</xref> introduced a method of estimating occupant CO<sub>2</sub> generation rates from measurements in mechanically ventilated buildings. <xref ref-type="bibr" rid="BIBR-13">(Jiang et al., 2016)</xref> used realtime CO<sub>2</sub> measurements as an estimator tool for CO<sub>2</sub> levels. <xref ref-type="bibr" rid="BIBR-4">(Bartlett et al., 2004)</xref> used numerical method to estimate CO<sub>2</sub> concentration in natural ventilation elementary school classrooms. They found that CO<sub>2</sub> were generated at a rate 404 mg/min per child and air quality in such classroom was lower than recommended air standard. In addition, Weekly et al. developed partial and ordinary differential equations for modeling and estimating CO<sub>2</sub> in a conference room setting (Weekly, <xref ref-type="bibr" rid="BIBR-28">(Weekly et al., 2015)</xref>). However, none of the above studies considered either increasing or decreasing rates of CO<sub>2</sub> levels in a classroom environment in hot and humid climate liked Thailand and modeling them in a function of carbon dioxide versus time. This paper aims at modeling CO<sub>2</sub> behavior and suggesting a method for designing ventilation fan capacity in classroom.</p></sec><sec><title>2. Research methodology</title><p>The study was implemented in one classroom of the King Mongkut's University of Technology North Bangkok. It had a size of 64 square meters, and a ceiling height of 3.5 meters. Fifteen students were present in the room. Initially, two experiments were undertaken involving increasing and decreasing levels of CO2. Rates of CO2 concentration in the classroom were recorded by an indoor air quality meter (Kimo AQ 200). Data was modelled using the linear regression method, which is a statistical technique for modelling the relationship between variables <xref ref-type="bibr" rid="BIBR-18">(Montgomery et al., 2012)</xref>. A straight-line function was selected to represent CO2 concentration data. Apprehension regarding using slope and y-interception represents the reason for using the straight-line form shown in Equation 1. The slope of a straight-line represents the relative increasing/decreasing rate of CO2 concentration. The y-interception represents the initial CO2 level in the room prior to occupancy.</p><p>y = ax + b (1)</p><p>where y = carbon dioxide concentration in ppm; x = time in minutes; a = slope of a straight-line or increasing/decreasing rate of CO2 concentration; and b = y-interception or initial level CO2 in the room.</p><p>The first and second experiments studied the increasing and decreasing of CO<sub>2</sub> as shown in <xref ref-type="fig" rid="figure-1">Figure 1</xref> and <xref ref-type="fig" rid="figure-2">Figure 2</xref>, respec- tively. Data were gathered on November 9, 2015 during 13:00 to 15:00 for the first experiment in <xref ref-type="fig" rid="figure-1">Figure 1</xref>. Carbon dioxide levels were recorded for two hours while students were present in the classroom. Nevertheless, actual CO<sub>2</sub> concentration has a single curvature, as shown in <xref ref-type="fig" rid="figure-1">Figure 1</xref>, and a 2nd degree polynomial function should be used for better correlation than a straight-line function. However, the polynomial can be best employed to estimate figures</p><p>within the range of the data known. It is not an effective model for making predictions because it tends to create double curvatures later. Therefore, a straight-line function was selected to represent increasing and decreasing rates of CO<sub>2</sub> in this research as an approximation model. In our experiments, two variables were found. Carbon dioxide levels in a classroom are a function of the time that students are present or left the classroom. The CO<sub>2</sub> concentration in <xref ref-type="fig" rid="figure-1">Figure 1</xref> can be represented by a straight-line function, as shown in Equation 2. It has a correlation value or R2 of 0.988. Thus, the increasing rate is 11.49 ppm/minute, as shown in the slope value.</p><p>y = 11.49x + 427</p><p>Data for the second experiement were gathered on November 9, 2015 during 15:15 to 17:15 as shown in <xref ref-type="fig" rid="figure-2">Figure 2</xref>. The decreasing rates of CO<sub>2</sub> concentration can be noticed after students left the classroom without ventilation fans having been operated. Such rates decrease naturally. All doors and windows were not open during the two-hour periods under consideration. A straight-line model for these data sets is shown in Equation 3. It has a correlation value or R2 of 0.994. CO<sub>2</sub> decreased at a rate of 3.67 ppm/minute. Correlation values of the decreasing rates of CO<sub>2</sub> function is obviously better than the increasing rates of CO<sub>2</sub> function.</p><p>y = −3.67x + 1801 (3)</p><fig id="figure-1" ignoredToc=""><label>Figure 1</label><caption><p>Increasing rates of CO2 in the experimental room</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/487/1321/5994" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig><fig id="figure-2" ignoredToc=""><label>Figure 2</label><caption><p>Decreasing rates of CO2 in the experimental room</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/487/1321/5995" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig><p>With respect to carbon dioxide levels, the Occupational Safety and Health Administration specifies the transitional limit of carbon dioxide in workplace as 5,000 ppm over a time weighted average <xref ref-type="bibr" rid="BIBR-19">(O.S.H.A., 2017)</xref>. A generally satisfactory level for indoor CO<sub>2</sub> concentration is between 1,000-1,200 ppm <xref ref-type="bibr" rid="BIBR-3">(A.S.H.R.A.E., 2014)</xref>. Therefore, the level of CO<sub>2</sub> used as a threshold in this research is 1,000 ppm, representing generally acceptable indoor air quality. The impact of employing ventilation fans is then studied by encouraging fresh air into the room and reducing CO<sub>2</sub> concentration, as shown in <xref ref-type="fig" rid="figure-3">Figure 3</xref>. It illustrates the data gained in the third experiment where ventilation fans were operated. The fans were operated manually when CO<sub>2</sub> levels inside the room exceeded 1000 ppm. The ventilation fans supply fresh air at a rate of 362 cfm, or 616 m3/hr. The actual ventilation rate, which ensures acceptable indoor air quality, is 24.13 cfm/person. This number is higher than that recommended by Thai standards. The minimum ventilation rate required for a classroom in Thailand stands at 15 cfm/person <xref ref-type="bibr" rid="BIBR-9">(Engineering Institute of Thailand (EIT, 2005)</xref>. The fresh air supply fan has enough power to disburse CO<sub>2</sub> at a rate under 1,000 ppm. The test duration in <xref ref-type="fig" rid="figure-3">Figure 3</xref> is less than 120 minutes due to classes adjourning before time.</p><p>From <xref ref-type="fig" rid="figure-3">Figure 3</xref>, the ability to dissipate CO<sub>2</sub> concentration can be determined by projecting the increasing rate beyond the 64th minutes with Equation 2, and subtracting with actual CO<sub>2</sub> figures for the period between the 64th and 101st minutes. Thus, we arrive at the projection shown in <xref ref-type="fig" rid="figure-4">Figure 4</xref>. The difference between the values of the two lines shown in the <xref ref-type="fig" rid="figure-4">Figure 4</xref> can be modelled as presented in Equation 4. It can estimate a removal rate of CO<sub>2</sub> while ventilation fan is operated. The installed ventilation fans, which have a capacity of 362 cfm, have the ability to remove CO<sub>2</sub> at a rate of approximately 13.4 ppm/minute. By dividing 362 cfm with 13.4 ppm/minute, 27 cubic foot of fresh air is required to remove one ppm of CO<sub>2</sub>.</p><p>y = 13.4x− 0.98 (4)</p><p>However, ventilation fans serve to channel hot and humid air into rooms since Thailand is subject to a typically hot and humid climate. Electricity consumption increases since air conditioning units work harder and consume more electricity to maintain the room temperature at 25 ◦C. Energy consumption is 1.28 and 1.91 kWh when ventilation fans are switched off and on, respectively. Through dispersing fresh air into the experiment room, electricity consumption increased by 49%. Thus, minimizing the use of ventilation fans can save energy.</p><fig id="figure-3" ignoredToc=""><label>Figure 3</label><caption><p>Operating a ventilation fan at a threshold of 1000 ppm</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/487/1321/5996" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig><fig id="figure-4" ignoredToc=""><label>Figure 4</label><caption><p>Using Equation 2 to project increasing rate of CO2 to determine the ability to dissipate CO2 by installed ventilation fan.</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/487/1321/5997" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig></sec><sec><title>3. Scenarios in operating ventilation fans</title><p>To maintain desirable indoor air quality, ventilation fans should be operated in rooms crowded with people. In this section, we will consider two scenarios concerned with the operation of a ventilation fan. The first scenario mimics situations when CO<sub>2</sub> sensors are set to operate ventilating fans at 1000 ppm, as shown in <xref ref-type="fig" rid="figure-5">Figure 5</xref>. Equation 2 was used to generate CO<sub>2</sub> in both scenarios. Meanwhile, the ability to remove CO<sub>2</sub> by fans as represented in <xref ref-type="fig" rid="figure-3">Figure 3</xref> is used to simulate the CO<sub>2</sub> concentration behaviors when operating ventilation fans. The total fan operating time is 54 minutes and the maximum CO<sub>2</sub> found is 1015 ppm.</p><p>Second, the alleviation of CO<sub>2</sub> concentration is studied after students having left the classroom. Two methods were considered involving alleviation under natural conditions and alleviation using ventilation fans, as shown in <xref ref-type="fig" rid="figure-6">Figure 6</xref>. During the first 120 minutes, classes were full with 15 students studying for two hours. Subsequently, students left the classroom. In <xref ref-type="fig" rid="figure-6">Figure 6</xref>, the top line represents the situation where CO<sub>2</sub> decreases naturally at a rate of 3.67 ppm per minute as determined from Equation 3. It is obvious that CO<sub>2</sub> cannot be removed to a satisfy level at 1000 ppm within one hour. The other line represents the situation where the ventilation fan was operating and students left the room for one hour. CO<sub>2</sub> concentration reduced at the combined rates of 3.67 and 13.4 ppm per minute as determined from Equations 3 and 4, respectively. When using the latter method indoor air quality quickly improves. CO<sub>2</sub> concentration diminishes by 1029 ppm in one hour. Since most classrooms in Thailand are vacant during lunch period from 12:00-13:00, schools should be strongly encouraged to operate ventilation fans during this period in order to restore air freshness in the classroom.</p></sec><sec><title>4. Selecting ventilation fan size</title><p>This section gives a guideline in selecting the appropriate size of ventilation fan based on developed models. The question under consideration concerns if 25 students are attending a class in a 64 square meter room, what is the appropriate capacity of a ventilation fan in cfm. The first step involves calculating the CO<sub>2</sub> emission of 25 students. Based on our data, CO<sub>2</sub> increases at a rate 11.49 ppm/minute for 15 students or 0.76 ppm/person/minute.</p><p>Therefore, the CO<sub>2</sub> emission rate for 25 students should be 19.15 ppm/minute, as shown in <xref ref-type="table" rid="table-1">Table 1</xref>. From earlier results, it is suggested that approximately 27 cubic feet of fresh air would be required to remove one ppm of CO<sub>2</sub>. Therefore, a ventilation fan capacity of 517 cfm is appropriate for this size of room and number of students. This number is higher than recommended by <xref ref-type="bibr" rid="BIBR-9">(Engineering Institute of Thailand (EIT, 2005)</xref> and <xref ref-type="bibr" rid="BIBR-3">(A.S.H.R.A.E., 2014)</xref> at 375 cfm and 187.5 cfm, respectively. Furthermore, the fan might be controlled by CO<sub>2</sub> sensor setting a threshold at 1000 ppm to turn the fan on and off at 800 ppm. Such operation could minimize energy consumption from air condition unit.</p><fig id="figure-5" ignoredToc=""><label>Figure 5</label><caption><p>Simulating an operation of a ventilation fan at a threshold of 1000 ppm.</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/487/1321/5998" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig><fig id="figure-6" ignoredToc=""><label>Figure 6</label><caption><p>Effects of CO2 removal by natural means and using ventilation fan after students have left a classroom</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/487/1321/5999" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig><table-wrap id="table-1" ignoredToc=""><label>Table 1</label><caption><p>Example in selecting the size of ventilation fans</p></caption><table frame="box" rules="all"><thead><tr><th colspan="1" rowspan="1" style="" align="center" valign="middle">Input</th><th colspan="1" rowspan="1" style="" align="center" valign="middle"/><th colspan="1" rowspan="1" style="" align="center" valign="middle"/></tr></thead><tbody><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">Number of Students</td><td colspan="1" rowspan="1" style="" align="center" valign="middle">25</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>persons</p></td></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">Size of Room</td><td colspan="1" rowspan="1" style="" align="center" valign="middle">64</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>sq.m.</p></td></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">Process</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"/><td colspan="1" rowspan="1" style="" align="center" valign="middle"/></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">Rate of CO<sub>2</sub> Generated By Students</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"/><td colspan="1" rowspan="1" style="" align="center" valign="middle"/></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">At a Rate of 0.76 ppm/person/minute</td><td colspan="1" rowspan="1" style="" align="center" valign="middle">19.15</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>ppm/min</p></td></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">Result</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"/><td colspan="1" rowspan="1" style="" align="center" valign="middle"/></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">Required Size of Fans to Maintain</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"/><td colspan="1" rowspan="1" style="" align="center" valign="middle"/></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">1000 ppm based on 27 cf/ppm</td><td colspan="1" rowspan="1" style="" align="center" valign="middle">517</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Cfm</p></td></tr></tbody></table></table-wrap></sec><sec><title>5. Conclusion</title><p>This research outlines details of preliminary models for estimating and predicting CO<sub>2</sub> concentration in classrooms. An example case study is presented. However, there are many limitations regarding the models since they are developed in terms of a classroom of 64 square meters with 15 students in attendance. More research could be undertaken to develop more versatile models encompassing different situations such as different size of rooms, ventilation fan capacities, and number of students. In our experiment, CO<sub>2</sub> increases at a rate 11.49 ppm/minute with 15 students, or 0.76 ppm/person/minute. It decreases naturally at a rate of 3.67 ppm per minute after students have left the classroom. This rate also depends on the nature of openings to the room. Guidelines for selecting the size of ventilation fans to reduce CO<sub>2</sub> concentration in classrooms have been suggested. The operation of mechanical ventilation may be required during vacant periods before students enter their next class in order to ensure acceptable indoor air quality for students. This research demonstrates how to develop a model for estimating CO<sub>2</sub> values in a classroom from an empirical study. An increasing rate of CO<sub>2</sub> due to students being present in the classroom were found at 0.76 ppm/person/minute. By using a ventilation fan, CO<sub>2</sub> level in room reduces. From our study, a 27 cubic foot of fresh air is required in order to remove one ppm of CO<sub>2</sub>. As a result, building designers can use this number as a guideline in selecting ventilation fan capacity.</p></sec><sec><title>6. Acknowledgments</title><p>This research is supported by the Royal Thai Government funding of fiscal year 2014 through the King Mongkut’s University of Technology North Bangkok (KMUTNB). The author wishes to thank them gratefully.</p></sec></body><back><ref-list><title>References</title><ref id="BIBR-1"><element-citation publication-type="article-journal"><article-title>The INDEX-PM project: health risks from exposure to indoor particulate matter</article-title><source>Fresenius Environmental Bulletin</source><volume>19</volume><issue>11</issue><person-group person-group-type="author"><name><surname>Arvanitis</surname><given-names>A.</given-names></name><name><surname>Kotzias</surname><given-names>D.</given-names></name><name><surname>Kephalopoulos</surname><given-names>S.</given-names></name><name><surname>Carrer</surname><given-names>P.</given-names></name><name><surname>Cavallo</surname><given-names>D.</given-names></name><name><surname>Cesaroni</surname><given-names>G.</given-names></name><name><surname>Fromme</surname><given-names>H.</given-names></name><etal/></person-group><year>2010</year><fpage>2458</fpage><lpage>2471</lpage><page-range>2458-2471</page-range></element-citation></ref><ref id="BIBR-2"><element-citation publication-type="book"><article-title>Air-Conditioning Engineers, &amp; American National Standards Institute</article-title><person-group person-group-type="author"><name><surname>Heating</surname><given-names>American Society</given-names></name><name name-style="given-only"><given-names>Refrigerating</given-names></name></person-group><year>2007</year><publisher-name>American Society of Heating, Refrigerating and Air-Conditioning Engineers</publisher-name></element-citation></ref><ref id="BIBR-3"><element-citation publication-type=""><article-title>ASHRAE Technical FAQ: What is the allowable level of carbon dioxide in an occupied space?</article-title><person-group person-group-type="author"><name name-style="given-only"><given-names>A.S.H.R.A.E.</given-names></name></person-group><year>2014</year><ext-link xlink:href="https://www.ashrae.org//File%20Library/Technical%20Resources/Technical%20FAQs/TC-04.03-FAQ-35.pdf" ext-link-type="uri" xlink:title="ASHRAE Technical FAQ: What is the allowable level of carbon dioxide in an occupied space?">Available from: https://www.ashrae.org//File%20Library/Technical%20Resources/Technical%20FAQs/TC-04.03-FAQ-35.pdf</ext-link></element-citation></ref><ref id="BIBR-4"><element-citation publication-type="article-journal"><article-title>Modeling of occupant-generated CO2 dynamics in naturally ventilated classrooms</article-title><source>Journal of Occupational and Environmental Hygiene</source><volume>1</volume><issue>3</issue><person-group person-group-type="author"><name><surname>Bartlett</surname><given-names>K.H.</given-names></name><name><surname>Martinez</surname><given-names>M.</given-names></name><name><surname>Bert</surname><given-names>J.</given-names></name></person-group><year>2004</year><fpage>139</fpage><lpage>148</lpage><page-range>139-148</page-range></element-citation></ref><ref id="BIBR-5"><element-citation publication-type="article-journal"><article-title>Review and extension of CO2-based methods to determine ventilation rates with application to school classrooms</article-title><source>International journal of environmental research and public health</source><volume>14</volume><issue>2</issue><person-group person-group-type="author"><name><surname>Batterman</surname><given-names>S.</given-names></name></person-group><year>2017</year><page-range>1456</page-range></element-citation></ref><ref id="BIBR-6"><element-citation publication-type="article-journal"><article-title>The health effects of nonindustrial indoor air pollution</article-title><source>Journal of Allergy and Clinical Immunology</source><volume>121</volume><person-group person-group-type="author"><name><surname>J.A.</surname><given-names>Bernstein</given-names></name><name><surname>N.</surname><given-names>Alexis</given-names></name><name><surname>H.</surname><given-names>Bacchus</given-names></name><name><surname>L.</surname><given-names>Bernstein</given-names></name><name><surname>P.</surname><given-names>Fritz</given-names></name><name><surname>E.</surname><given-names>Horner</given-names></name><name><surname>N.</surname><given-names>Li</given-names></name><name><surname>A.</surname><given-names>Nel</given-names></name><name><surname>J.</surname><given-names>Oullette</given-names></name><name><surname>K.</surname><given-names>Reijula</given-names></name><name><surname>T.</surname><given-names>Reponen</given-names></name><name><surname>J.</surname><given-names>Seltzer</given-names></name><name><surname>A.</surname><given-names>Smith</given-names></name><name><surname>S.M</surname><given-names>Tarlo</given-names></name></person-group><year>2008</year><fpage>585</fpage><lpage>591</lpage><page-range>585-591</page-range></element-citation></ref><ref id="BIBR-7"><element-citation publication-type="article-journal"><article-title>Development and application of an indoor air quality audit to an air-conditioned building in Singapore</article-title><source>Building and Environment</source><volume>36</volume><issue>2</issue><person-group person-group-type="author"><name><surname>Cheong</surname><given-names>K.W.</given-names></name><name><surname>Chong</surname><given-names>K.Y.</given-names></name></person-group><year>2001</year><fpage>181</fpage><lpage>188</lpage><page-range>181-188</page-range></element-citation></ref><ref id="BIBR-8"><element-citation publication-type="article-journal"><article-title>Ventilation rates in schools</article-title><source>Building and Environment</source><volume>43</volume><issue>3</issue><person-group person-group-type="author"><name><surname>Clements-Croome</surname><given-names>D.J.</given-names></name><name><surname>Awbi</surname><given-names>H.B.</given-names></name><name><surname>Bakó-Biró</surname><given-names>Z.</given-names></name><name><surname>Kochhar</surname><given-names>N.</given-names></name><name><surname>Williams</surname><given-names>M.</given-names></name></person-group><year>2008</year><fpage>362</fpage><lpage>367</lpage><page-range>362-367</page-range></element-citation></ref><ref id="BIBR-9"><element-citation publication-type="article-journal"><article-title>Engineering Institute of Thailand (EIT</article-title><source>EIT Standard</source><volume>Number 3010</volume><year>2005</year><publisher-loc>Bangkok</publisher-loc></element-citation></ref><ref id="BIBR-10"><element-citation publication-type="article-journal"><article-title>Ventilation system type, classroom environmental quality and pupils' perceptions and symptoms</article-title><source>Building and Environment</source><volume>75</volume><person-group person-group-type="author"><name><surname>Gao</surname><given-names>J.</given-names></name><name><surname>Wargocki</surname><given-names>P.</given-names></name><name><surname>Wang</surname><given-names>Y.</given-names></name></person-group><year>2014</year><fpage>46</fpage><lpage>57</lpage><page-range>46-57</page-range></element-citation></ref><ref id="BIBR-11"><element-citation publication-type="article-journal"><article-title>Control of CO2 in a naturally ventilated classroom</article-title><source>Energy and Buildings</source><volume>40</volume><issue>4</issue><person-group person-group-type="author"><name><surname>Griffiths</surname><given-names>M.</given-names></name><name><surname>Eftekhari</surname><given-names>M.</given-names></name></person-group><year>2008</year><fpage>556</fpage><lpage>560</lpage><page-range>556-560</page-range></element-citation></ref><ref id="BIBR-12"><element-citation publication-type="article-journal"><article-title>Particulate matter and carbon dioxide in classrooms–the impact of cleaning and ventilation</article-title><source>International Journal of Hygiene and Environmental Health</source><volume>212</volume><issue>1</issue><person-group person-group-type="author"><name><surname>Heudorf</surname><given-names>U.</given-names></name><name><surname>Neitzert</surname><given-names>V.</given-names></name><name><surname>Spark</surname><given-names>J.</given-names></name></person-group><year>2009</year><fpage>45</fpage><lpage>55</lpage><page-range>45-55</page-range></element-citation></ref><ref id="BIBR-13"><element-citation publication-type="article-journal"><article-title>Indoor occupancy estimation from carbon dioxide concentration</article-title><source>Energy and Buildings</source><volume>131</volume><person-group person-group-type="author"><name><surname>Jiang</surname><given-names>C.</given-names></name><name><surname>Masood</surname><given-names>M.K.</given-names></name><name><surname>Soh</surname><given-names>Y.C.</given-names></name><name><surname>Li</surname><given-names>H.</given-names></name></person-group><year>2016</year><fpage>132</fpage><lpage>141</lpage><page-range>132-141</page-range></element-citation></ref><ref id="BIBR-14"><element-citation publication-type="article-journal"><article-title>An indoor air quality wireless monitoring network witha carbon dioxide prediction model</article-title><source>Fresenius Environmental Bulletin</source><volume>25</volume><issue>10</issue><person-group person-group-type="author"><name><surname>Kang</surname><given-names>S.Y.</given-names></name><name><surname>Tseng</surname><given-names>C.H.</given-names></name><name><surname>Wang</surname><given-names>A.J.</given-names></name><name><surname>Shih</surname><given-names>Y.H.</given-names></name><name><surname>Nguyen</surname><given-names>N.T.</given-names></name></person-group><year>2016</year><fpage>3875</fpage><lpage>3885</lpage><page-range>3875-3885</page-range></element-citation></ref><ref id="BIBR-15"><element-citation publication-type="article-journal"><article-title>Building design and indoor air quality-experience and prospects</article-title><source>Fresenius Environmental Bulletin</source><volume>26</volume><issue>1</issue><person-group person-group-type="author"><name><surname>Kotzias</surname><given-names>D.</given-names></name><name><surname>Pilidis</surname><given-names>G.</given-names></name></person-group><year>2017</year><fpage>323</fpage><lpage>326</lpage><page-range>323-326</page-range></element-citation></ref><ref id="BIBR-16"><element-citation publication-type="article-journal"><article-title>A methodology for estimating occupant CO2 source generation rates from measurements in small commercial buildings</article-title><source>Building and Environment</source><volume>42</volume><issue>2</issue><person-group person-group-type="author"><name><surname>Lawrence</surname><given-names>T.M.</given-names></name><name><surname>Braun</surname><given-names>J.E.</given-names></name></person-group><year>2007</year><fpage>623</fpage><lpage>639</lpage><page-range>623-639</page-range></element-citation></ref><ref id="BIBR-17"><element-citation publication-type="article-journal"><article-title>A novel methodology for estimating space air change rates and occupant CO2 generation rates from measurements in mechanically-ventilated buildings</article-title><source>Building and Environment</source><volume>45</volume><issue>5</issue><person-group person-group-type="author"><name><surname>Lu</surname><given-names>T.</given-names></name><name><surname>Knuutila</surname><given-names>A.</given-names></name><name><surname>Viljanen</surname><given-names>M.</given-names></name><name><surname>Lu</surname><given-names>X.</given-names></name></person-group><year>2010</year><fpage>1161</fpage><lpage>1172</lpage><page-range>1161-1172</page-range></element-citation></ref><ref id="BIBR-18"><element-citation publication-type="book"><article-title>Introduction to linear regression analysis</article-title><volume>821</volume><person-group person-group-type="author"><name><surname>Montgomery</surname><given-names>D.C.</given-names></name><name><surname>Peck</surname><given-names>E.A.</given-names></name><name><surname>Vining</surname><given-names>G.G.</given-names></name></person-group><year>2012</year><publisher-name>John Wiley &amp; Sons</publisher-name></element-citation></ref><ref id="BIBR-19"><element-citation publication-type=""><article-title>Carbon Dioxide, Available from: &lt; https://www.osha.gov/dts/sltc/methods/inorganic/id172/id172.html &gt;</article-title><person-group person-group-type="author"><name name-style="given-only"><given-names>O.S.H.A.</given-names></name></person-group><year>2017</year></element-citation></ref><ref id="BIBR-20"><element-citation publication-type="article-journal"><article-title>Field measurement of ventilation rates</article-title><source>Indoor Air</source><volume>26</volume><issue>1</issue><person-group person-group-type="author"><name><surname>Persily</surname><given-names>A.K.</given-names></name></person-group><year>2016</year><fpage>97</fpage><lpage>111</lpage><page-range>97-111</page-range></element-citation></ref><ref id="BIBR-21"><element-citation publication-type="article-journal"><article-title>Carbon dioxide generation rates for building occupants</article-title><source>Indoor air</source><volume>27</volume><issue>5</issue><person-group person-group-type="author"><name><surname>Persily</surname><given-names>A.</given-names></name><name><surname>Jonge</surname><given-names>L.</given-names></name></person-group><year>2017</year><fpage>868</fpage><lpage>879</lpage><page-range>868-879</page-range></element-citation></ref><ref id="BIBR-22"><element-citation publication-type="article-journal"><article-title>Why Measure Carbon Dioxide Inside Buildings? Washington State University Extension Energy Program</article-title><source>Available</source><issue>ttp://www.energy.wsu.edu/Documents/CO2inbuildings.pdf&gt;</issue><person-group person-group-type="author"><name><surname>Prill</surname><given-names>R.</given-names></name></person-group><year>2000</year><page-range>9</page-range></element-citation></ref><ref id="BIBR-23"><element-citation publication-type="article-journal"><article-title>Indoor indoor air quality in residences at the city of kozani, greece: effects of the house location</article-title><source>Fresenius Environmental Bulletin</source><volume>26</volume><issue>1</issue><person-group person-group-type="author"><name><surname>Sabaziotis</surname><given-names>V.</given-names></name><name><surname>Galinos</surname><given-names>K.</given-names></name><name><surname>Missia</surname><given-names>D.</given-names></name><name><surname>Kalimeri</surname><given-names>K.K.</given-names></name><name><surname>Tolis</surname><given-names>E.I.</given-names></name><name><surname>Bartzis</surname><given-names>J.G.</given-names></name></person-group><year>2017</year><fpage>255</fpage><lpage>262</lpage><page-range>255-262</page-range></element-citation></ref><ref id="BIBR-24"><element-citation publication-type="article-journal"><article-title>VOCS, PAHS and ions measurements in an office environment in the vicinity of a small industry</article-title><source>Fresenius Environmental Bulletin</source><volume>26</volume><issue>1</issue><person-group person-group-type="author"><name><surname>Sakellaris</surname><given-names>I.A.</given-names></name><name><surname>Tolis</surname><given-names>E.I.</given-names></name><name><surname>Saraga</surname><given-names>D.E.</given-names></name><name><surname>Bartzis</surname><given-names>J.G.</given-names></name></person-group><year>2017</year><fpage>292</fpage><lpage>300</lpage><page-range>292-300</page-range></element-citation></ref><ref id="BIBR-25"><element-citation publication-type="article-journal"><article-title>Indoor air quality and thermal comfort optimization in classrooms developing an automatic system for windows opening and closing</article-title><source>Energy and Buildings</source><volume>139</volume><person-group person-group-type="author"><name><surname>Stazi</surname><given-names>F.</given-names></name><name><surname>Naspi</surname><given-names>F.</given-names></name><name><surname>Ulpiani</surname><given-names>G.</given-names></name><name><surname>Perna</surname><given-names>C.</given-names></name></person-group><year>2017</year><fpage>732</fpage><lpage>746</lpage><page-range>732-746</page-range></element-citation></ref><ref id="BIBR-26"><element-citation publication-type="paper-conference"><article-title>A model-based control of CO2 concentration in multi-zone ACB air-conditioning systems</article-title><source>2016 12th IEEE International Conference on Control and Automation (ICCA</source><person-group person-group-type="author"><name><surname>Wang</surname><given-names>H.</given-names></name><name><surname>Xie</surname><given-names>L.</given-names></name><name><surname>Liu</surname><given-names>S.</given-names></name><name><surname>Xu</surname><given-names>J.</given-names></name></person-group><year>2016</year><fpage>467</fpage><lpage>472</lpage><page-range>467-472</page-range><publisher-name>IEEE</publisher-name></element-citation></ref><ref id="BIBR-27"><element-citation publication-type="article-journal"><article-title>Use of visual CO 2 feedback as a retrofit solution for improving classroom air quality</article-title><source>Indoor Air</source><volume>25</volume><issue>1</issue><person-group person-group-type="author"><name><surname>Wargocki</surname><given-names>P.</given-names></name><name><surname>Silva</surname><given-names>N.A.F.</given-names></name></person-group><year>2015</year><fpage>105</fpage><lpage>114</lpage><page-range>105-114</page-range></element-citation></ref><ref id="BIBR-28"><element-citation publication-type="article-journal"><article-title>Modeling and estimation of the humans' effect on the CO 2 dynamics inside a conference room</article-title><source>IEEE Transactions on Control Systems Technology</source><volume>23</volume><issue>5</issue><person-group person-group-type="author"><name><surname>Weekly</surname><given-names>K.</given-names></name><name><surname>Bekiaris-Liberis</surname><given-names>N.</given-names></name><name><surname>Jin</surname><given-names>M.</given-names></name><name><surname>Bayen</surname><given-names>A.M.</given-names></name></person-group><year>2015</year><fpage>1770</fpage><lpage>1781</lpage><page-range>1770-1781</page-range></element-citation></ref><ref id="BIBR-29"><element-citation publication-type="article-journal"><article-title>A transient ventilation demand model for air-conditioned offices</article-title><source>Applied Energy</source><volume>85</volume><issue>7</issue><person-group person-group-type="author"><name><surname>Wong</surname><given-names>L.T.</given-names></name><name><surname>Mui</surname><given-names>K.W.</given-names></name></person-group><year>2008</year><fpage>545</fpage><lpage>554</lpage><page-range>545-554</page-range></element-citation></ref><ref id="BIBR-30"><element-citation publication-type="article-journal"><article-title>An energy impact assessment of indoor air quality acceptance for air-conditioned offices</article-title><source>Energy conversion and management</source><volume>49</volume><issue>10</issue><person-group person-group-type="author"><name><surname>Wong</surname><given-names>L.T.</given-names></name><name><surname>Mui</surname><given-names>K.W.</given-names></name><name><surname>Shi</surname><given-names>K.L.</given-names></name><name><surname>Hui</surname><given-names>P.S.</given-names></name></person-group><year>2008</year><fpage>2815</fpage><lpage>2819</lpage><page-range>2815-2819</page-range></element-citation></ref></ref-list></back></article>
