<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="1.3" article-type="research-article"><front><journal-meta><journal-id journal-id-type="issn">2357-0857</journal-id><journal-title-group><journal-title>Environmental Science &amp; Sustainable Development</journal-title><abbrev-journal-title>ESSD</abbrev-journal-title></journal-title-group><issn pub-type="epub">2357-0857</issn><issn pub-type="ppub">2357-0849</issn><publisher><publisher-name>IEREK Press</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21625/essd.v9i3.1072</article-id><article-categories/><title-group><article-title>Analysing Indoor Air Pollution: A Study on Pollutant Levels and Air Quality Assessment in Social Housing Properties</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Narayanan</surname><given-names>Vishnupriya Valeriparambil</given-names></name><address><country>United Kingdom</country></address><xref ref-type="aff" rid="AFF-1"/></contrib><contrib contrib-type="author"><name><surname>Shaikh</surname><given-names>Roshina Rabbani</given-names></name><address><country>United Kingdom</country></address><xref ref-type="aff" rid="AFF-1"/></contrib><contrib contrib-type="author"><name><surname>Hashemi</surname><given-names>Arman</given-names></name><address><country>United Kingdom</country></address><xref ref-type="aff" rid="AFF-2"/></contrib><contrib contrib-type="author"><name><surname>Elsharkawy</surname><given-names>Heba</given-names></name><address><country>United Kingdom</country></address><xref ref-type="aff" rid="AFF-3"/></contrib><contrib contrib-type="author"><name><surname>Newport</surname><given-names>Darryl</given-names></name><address><country>United Kingdom</country></address><xref ref-type="aff" rid="AFF-4"/></contrib><contrib contrib-type="author"><name><surname>Basaly</surname><given-names>Lucienne G.</given-names></name><address><country>United Kingdom</country></address><xref ref-type="aff" rid="AFF-5"/></contrib><aff id="AFF-1">Research Assistant, School of Architecture Computing and Engineering, University of East London, United Kingdom</aff><aff id="AFF-2">Senior Lecturer, School of Architecture Computing and Engineering, University of East London, United Kingdom</aff><aff id="AFF-3">Associate Professor, Kingston School of Arts, Kingston University, United Kingdom</aff><aff id="AFF-4">Professor, Energy and Sustainable Development, University of Suffolk, United Kingdom</aff><aff id="AFF-5">Postdoctoral Research Fellow, School of Architecture Computing and Engineering, University of East London, United Kingdom</aff></contrib-group><contrib-group><contrib contrib-type="editor"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-8754-3523</contrib-id><name><surname>Spina</surname><given-names>Professor Lucia Della</given-names></name><address><country>Italy</country></address></contrib></contrib-group><pub-date date-type="pub" iso-8601-date="2024-9-30" publication-format="electronic"><day>30</day><month>9</month><year>2024</year></pub-date><pub-date date-type="collection" iso-8601-date="2024-9-30" publication-format="electronic"><day>30</day><month>9</month><year>2024</year></pub-date><volume>3</volume><issue>9</issue><issue-title>Towards Sustainable and Resilient Cities</issue-title><fpage>47</fpage><lpage>57</lpage><history><date date-type="received" iso-8601-date="2024-4-7"><day>7</day><month>4</month><year>2024</year></date><date date-type="accepted" iso-8601-date="2024-9-23"><day>23</day><month>9</month><year>2024</year></date></history><permissions><copyright-statement>© 2024 The Authors. Published by IEREK Press. This is an open-access article under the CC BY license (https://creativecommons.org/licenses/by/4.0/). Peer review under the responsibility of ESSD’s International Scientific Committee of Reviewers.</copyright-statement><copyright-year>2024</copyright-year><copyright-holder>Vishnupriya Valeriparambil Narayanan, Roshina Rabbani Shaikh, Arman Hashemi, Heba Elsharkawy, Darryl Newport, Lucienne G. Basaly</copyright-holder><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/">http://creativecommons.org/licenses/by/4.0</ali:license_ref><license-p>This work is licensed under a Creative Commons Attribution 4.0 International License.The Author shall grant to the Publisher and its agents the nonexclusive perpetual right and license to publish, archive, and make accessible the Work in whole or in part in all forms of media now or hereafter known under a Creative Commons Attribution 4.0 License or its equivalent, which, for the avoidance of doubt, allows others to copy, distribute, and transmit the Work under the following conditions:Attribution: other users must attribute the Work in the manner specified by the author as indicated on the journal Web site;With the understanding that the above condition can be waived with permission from the Author and that where the Work or any of its elements is in the public domain under applicable law, that status is in no way affected by the license.The Author is able to enter into separate, additional contractual arrangements for the nonexclusive distribution of the journal's published version of the Work (e.g., post it to an institutional repository or publish it in a book), as long as there is provided in the document an acknowledgement of its initial publication in this journal.Authors are permitted and encouraged to post online a pre-publication manuscript (but not the Publisher's final formatted PDF version of the Work) in institutional repositories or on their Websites prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (see The Effect of Open Access). Any such posting made before acceptance and publication of the Work shall be updated upon publication to include a reference to the Publisher-assigned DOI (Digital Object Identifier) and a link to the online abstract for the final published Work in the Journal.Upon Publisher's request, the Author agrees to furnish promptly to Publisher, at the Author's own expense, written evidence of the permissions, licenses, and consents for use of third-party material included within the Work, except as determined by Publisher to be covered by the principles of Fair Use.The Author represents and warrants that:The Work is the Author's original work;The Author has not transferred, and will not transfer, exclusive rights in the Work to any third party;The Work is not pending review or under consideration by another publisher;The Work has not previously been published;The Work contains no misrepresentation or infringement of the Work or property of other authors or third parties; andThe Work contains no libel, invasion of privacy, or other unlawful matter.The Author agrees to indemnify and hold Publisher harmless from Author's breach of the representations and warranties contained in Paragraph 7 above, as well as any claim or proceeding relating to Publisher's use and publication of any content contained in the Work, including third-party content.This work is licensed under a Creative Commons Attribution 4.0 International License.</license-p></license></permissions><self-uri xlink:href="https://press.ierek.com/index.php/ESSD/article/view/47-57" xlink:title="Analysing Indoor Air Pollution: A Study on Pollutant Levels and Air Quality Assessment in Social Housing Properties">Analysing Indoor Air Pollution: A Study on Pollutant Levels and Air Quality Assessment in Social Housing Properties</self-uri><abstract><p>Amid growing concerns over Indoor Air Quality (IAQ), this paper presents a comprehensive analysis of pollutants to assess the environmental health in a few Case Study Buildings (CSBs). The main objectives were to evaluate the levels of key Indoor Air Pollutants (IAPs) (PM<sub>10</sub>, PM<sub>2.5</sub>, CO, CO<sub>2</sub>, TVOCs) and relative humidity across multiple social housing properties and to analyze how occupant behaviormay affect IAQ. Utilizing quantitative measurements, the study investigates the range and exposure of the building occupants to IAPs. The methodology involves the systematic measurement of IAPs through the installation of data loggers, focusing on pollutant levels to evaluate air quality across multiple CSBs. Findings show fluctuation in pollutant levels, with some IAPs demonstrating consistently within the acceptable range while others exhibit sporadic spikes in pollutant concentrations. The results indicate that significant attention should be given to PM<sub>10</sub>, CO, and VOCs. This study underscores the importance of continuous monitoring and targeted interventions to mitigate poor IAQ and ensure healthier indoor environments for building occupants. Further research and implementation of effective measures are imperative to safeguard public health and well-being.</p></abstract><kwd-group><kwd>Indoor air quality</kwd><kwd>Indoor air pollutants</kwd><kwd>Occupant health</kwd><kwd>Energy efficiency</kwd></kwd-group><custom-meta-group><custom-meta><meta-name>File created by JATS Editor</meta-name><meta-value><ext-link ext-link-type="uri" xlink:href="https://jatseditor.com" xlink:title="JATS Editor">JATS Editor</ext-link></meta-value></custom-meta><custom-meta><meta-name>issue-created-year</meta-name><meta-value>2024</meta-value></custom-meta></custom-meta-group></article-meta></front><body><sec><title>1. Introduction</title><p>In recent years, there has been a growing awareness of the profound impact of IAQ on human health and wellbeing. The significance of this issue is underscored by studies indicating that indoor environments often harbor higher concentrations of pollutants compared to outdoor spaces, putting individuals at risk of various health issues <xref ref-type="bibr" rid="BIBR-5">(Chenari et al., 2016)</xref>. This is concerning given that most people spend approximately 90% of their time indoors <xref ref-type="bibr" rid="BIBR-11">(Laumbach &amp; Kipen, 2012)</xref>. While IAQ assessments are crucial across all types of dwellings, special attention is warranted for social housing properties. Residents in these settings, already among the most vulnerable populations facing economic, social, and health inequalities <xref ref-type="bibr" rid="BIBR-3">(Baker et al., 2016)</xref>, are further impacted by inadequate ventilation systems and maintenance protocols in their living spaces <xref ref-type="bibr" rid="BIBR-24">(Vardoulakis et al., 2015)</xref>. Poor IAQ in residential buildings can lead to various adverse health effects, ranging from minor discomfort to severe respiratory issues and chronic illnesses <xref ref-type="bibr" rid="BIBR-16">(Mavrogianni et al., 2022)</xref>. Several studies have linked exposure to indoor air pollutants with increased risks of respiratory infections, asthma exacerbations, allergic reactions, and even cardiovascular diseases <xref ref-type="bibr" rid="BIBR-4">(Beizaee et al., 2021)</xref>. Prolonged exposure to high levels of pollutants like carbon monoxide can potentially lead to neurological damage and even death <xref ref-type="bibr" rid="BIBR-2">(Baeza_Romero et al., 2022)</xref>. Low-income families may be more likely to experience poor IAQ due to substandard housing conditions and inadequate resources for addressing the issue <xref ref-type="bibr" rid="BIBR-18">(National Institute of Environmental Health Sciences, 2024)</xref>. Exposure to indoor air pollution, both short-term and long-term, can lead to a wide range of diseases <xref ref-type="bibr" rid="BIBR-10">(Koivisto et al., 2019)</xref>. Therefore, the development of monitoring systems is crucial for IAQ control. Effective IAQ control necessitates determining the sources of air pollution <xref ref-type="bibr" rid="BIBR-22">(Tran et al., 2020)</xref>. IAQ in residential buildings is significantly influenced by three primary factors <xref ref-type="bibr" rid="BIBR-14">(Marć et al., 2018)</xref><xref ref-type="bibr" rid="BIBR-19">(Peng et al., 2017)</xref>: (i) outdoor air quality, (ii) human activities within buildings, and (iii) building materials, equipment, and furniture. Outdoor contaminant concentrations and building airtightness greatly impact IAQ due to the potential for indoor transportation of outdoor contaminants <xref ref-type="bibr" rid="BIBR-20">(Poupard et al., 2005)</xref>. IAQ can be impacted by the materials used in the construction and furnishing of buildings. Many building materials, furniture, and household items emit volatile organic compounds (VOCs) that can contribute to poor IAQ <xref ref-type="bibr" rid="BIBR-27">(Wolkoff et al., 2018)</xref>. Additionally, inadequate ventilation and poor maintenance of air filtration systems can exacerbate the problem by allowing these pollutants to accumulate in the indoor environment <xref ref-type="bibr" rid="BIBR-28">(Yadav et al., 2023)</xref>. Furthermore, specific populations may be more vulnerable to the negative effects of poor IAQ. For example, children, the elderly, and individuals with pre-existing respiratory conditions such as asthma are at higher risk of health problems due to exposure to indoor pollutants <xref ref-type="bibr" rid="BIBR-9">(Hanssen et al., 2018)</xref>.</p><p>IAQ is greatly impacted by occupant behavior and environmental circumstances. Commonplace actions in communal housing, like using specific home goods, cooking improperly without enough ventilation as well as smoking indoors, can emit pollutants into the air <xref ref-type="bibr" rid="BIBR-29">(Zhou et al., 2022)</xref>. These activities also expose residents to various dangerous compounds and worsen IAQ. A lack of knowledge and instruction on the consequences of these actions can make the problem worse. According to Mannan and Al-Ghamdi, 2021, smoking indoors releases toxic compounds that linger and seriously endanger the health of those who live there, and not only smoking but also lightning items such as candles or incense sticks or items generating fumes make it a notable factor in poor IAQ. Apart from obvious reasons such as smoking and cooking some more habits of occupants may affect the IAQ. Cleaning habits and poor ventilation have also been important factors in degrading IAQ, several cleaning products, highly fragranced products, and air fresheners all add to indoor pollution. When occupants choose these devices without sufficient ventilation, they unintentionally bring dangerous materials into their lives. Another essential component of IAQ is moisture management. It has been observed that certain behaviors such as drying clothes inside, increase the humidity within, especially without ventilation or less ventilation which consequently fosters the formation of mold <xref ref-type="bibr" rid="BIBR-8">(H. et al., 2021)</xref>. IAQ issues can be exacerbated by indoor overpopulation, as it can lead to an increase in carbon dioxide levels <xref ref-type="bibr" rid="BIBR-15">(T. et al., 2020)</xref>. Regular monitoring of IAQ levels and occupant education on the importance of maintaining good IAQ are also crucial components of a comprehensive IAQ management strategy <xref ref-type="bibr" rid="BIBR-17">(Mendell et al., 2016)</xref>. Improving IAQ in residential buildings requires a multifaceted approach that addresses both the sources of pollution and the ventilation systems. Effective source control measures can include minimizing the use of products that emit pollutants, proper maintenance of combustion appliances, and implementing moisture control strategies <xref ref-type="bibr" rid="">(WHO, 2010)</xref>. Additionally, ensuring adequate ventilation through mechanical systems or natural ventilation can help dilute and remove pollutants from the indoor environment <xref ref-type="bibr" rid="BIBR-5">(Chenari et al., 2016)</xref>.</p><p>This paper embarks on a thorough exploration of IAPs within various social housing properties, aiming to not only evaluate how the behaviors of occupants in different flats can affect the IAQ but also scrutinize potential exposure risks for residents.</p></sec><sec><title>2. Methodology</title><p>The study concentrates on measuring key pollutants such as Particulate Matters (PM<sub>10</sub> and PM<sub>2.5</sub>), Carbon Monoxide (CO), Carbon Dioxide (CO<sub>2</sub>), and Total Volatile Organic Compounds (TVOCs), along with assessing temperature and humidity levels on an average of 24 hours across seven Case Study Buildings (CSBs). Measurements were taken during winter and pollutants such as CO, CO<sub>2</sub>, TVOC, PM<sub>10</sub>, PM<sub>2.5</sub>, and humidity were recorded using DL-1038 (<xref ref-type="fig" rid="figure-10">Figure 1</xref>. a). HOBO MX1102A CO2 Monitor &amp; Data Logger (<xref ref-type="fig" rid="figure-10">Figure 1</xref>. b) were also used to measure the temperature, relative humidity, and CO<sub>2</sub> levels.</p><fig id="figure-10" ignoredToc=""><label>Figure 1</label><caption><p>a) DL-1038. b) HOBO MX1102A CO2 Monitor &amp; Data Logger. (Source: The authors)</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/47-57/1192/4736" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig><p>Data loggers were installed in the living rooms for 37 days starting from November 27, 2023, and were monitored at 15-minute intervals until January 2, 2024. Daily average readings of each pollutant were analyzed to assess IAQ and elucidate the impact of resident behavior on pollutant levels.</p><p>The research follows the IAQ guidelines and standards from organizations such as the World Health Organisation (WHO), Chartered Institution of Building Services Engineers (CIBSE), American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE), and Leadership in Energy and Environmental Designs (LEEDs) rating system. <xref ref-type="table" rid="table-1">Table 1</xref> summarizes the IAQ guidelines and standards used to analyze the collected data.</p><table-wrap id="table-1" ignoredToc=""><label>Table 1</label><caption><p>IAQ guidelines and standards</p></caption><table frame="box" rules="all"><thead><tr><th colspan="1" rowspan="1" style="" align="left" valign="top"><p>Pollutant</p></th><th colspan="1" rowspan="1" style="" align="left" valign="top"><p>Guideline Value</p></th><th colspan="1" rowspan="1" style="" align="left" valign="top"><p>Source</p></th></tr></thead><tbody><tr><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>Carbon monoxide</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>6 ppm (24 hr average)</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p><xref ref-type="bibr" rid="BIBR-26">(W.H.O., 2021)</xref></p></td></tr><tr><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>Carbon dioxide</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>1000 ppm</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p><xref ref-type="bibr" rid="BIBR-1">(A.S.H.R.A.E., 2019)</xref></p></td></tr><tr><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>TVOCs</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>300 μg/m<sup>3</sup> 1 (8 hr average)</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p><xref ref-type="bibr" rid="BIBR-6">(TM40, 2020)</xref></p></td></tr><tr><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>PM<sub>2.5</sub></p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>15 μg/m<sup>3</sup> (24 hr average)</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p><xref ref-type="bibr" rid="BIBR-26">(W.H.O., 2021)</xref></p></td></tr><tr><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>PM<sub>10</sub></p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>45 μg/m<sup>3</sup> (24 hr average)</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p><xref ref-type="bibr" rid="BIBR-26">(W.H.O., 2021)</xref></p></td></tr><tr><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>Relative Humidity</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>40-70%</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><p><xref ref-type="bibr" rid="BIBR-7">(C.I.B.S.E., 2021)</xref></p></td></tr><tr><td colspan="1" rowspan="1" style="" align="left" valign="top"><p>Temperature (Winter) – Living Areas</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><break/><p>22-23°C</p></td><td colspan="1" rowspan="1" style="" align="left" valign="top"><break/><p><xref ref-type="bibr" rid="BIBR-7">(C.I.B.S.E., 2021)</xref></p></td></tr></tbody></table><table-wrap-foot><p><sup>1</sup> According to Arc's Guide to Reentry v1.1 <xref ref-type="bibr" rid="BIBR-21">(Pyke, 2020)</xref>, a conversion factor of 3.767 is used to convert μg/m<sup>3</sup> to ppb to get a value approximately equal to 80 ppb.</p></table-wrap-foot></table-wrap><sec><title>2.1. The Case Study Buildings</title><p>The CSBs were constructed between the 1950s/1966s and have cavity walls and double-glazed windows and are located in an urban area in the London Borough of Newhan. The occupants included pregnant women, elderly and young people, and people who smoked (vaped), burned candles or incense sticks, used air fresheners as well as used household cleaning materials. In terms of occupancy, the majority of the flats were always occupied apart from one which was occasionally occupied. The number of occupants is as follows: 2 flats (Flat A and B) had 2 occupants, 3 flats (Flat C, D, and G) had single occupancy, 1 flat (Flat E) had 3 occupants, and 1 flat (Flat F) had 4 occupants. All CSBs were 1-bed, and 2-bedroom apartments most of which were located on the top and middle floors with facing North-South orientation, except from Flat C which was located underground and was facing East-West. All had central gas heating systems and mechanical ventilation units to improve background ventilation, however, they were not used (for various reasons including noise and cold draft) by the tenants. <xref ref-type="table" rid="table-2">Table 2</xref> summarizes the key characteristics of each flat in the case study, including location, number of occupants, area (number of bedrooms), and orientation.</p><fig id="figure-2" ignoredToc=""><label>Figure 2</label><caption><p>Case Study Buildings (Source: The authors)</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/47-57/1192/4737" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig><table-wrap id="table-2" ignoredToc=""><label>Table 2</label><caption><p>Summary of Case Study Building Characteristics (Source: The authors)</p></caption><table frame="box" rules="all"><thead><tr><th colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Flat</p></th><th colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Location</p></th><th colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Number of Occupants</p></th><th colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Number of Bedrooms</p></th><th colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Orientation</p></th></tr></thead><tbody><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>A</p></td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Building A</p></td><td colspan="1" rowspan="1" style="" align="center" valign="middle">2</td><td colspan="1" rowspan="1" style="" align="center" valign="middle">1</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>North-South</p></td></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">B</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Building A</p></td><td colspan="1" rowspan="1" style="" align="center" valign="middle">2</td><td colspan="1" rowspan="1" style="" align="center" valign="middle">1</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>North-South</p></td></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">C</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Building B</p></td><td colspan="1" rowspan="1" style="" align="center" valign="middle">1</td><td colspan="1" rowspan="1" style="" align="center" valign="middle">1</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>East-West</p></td></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>D</p></td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Building A</p></td><td colspan="1" rowspan="1" style="" align="center" valign="middle">1</td><td colspan="1" rowspan="1" style="" align="center" valign="middle">1</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>North-South</p></td></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">E</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Building A</p></td><td colspan="1" rowspan="1" style="" align="center" valign="middle">3</td><td colspan="1" rowspan="1" style="" align="center" valign="middle">2</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>North-South</p></td></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle">F</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Building A</p></td><td colspan="1" rowspan="1" style="" align="center" valign="middle">4</td><td colspan="1" rowspan="1" style="" align="center" valign="middle">2</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>North-South</p></td></tr><tr><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>G</p></td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>Building A</p></td><td colspan="1" rowspan="1" style="" align="center" valign="middle">1</td><td colspan="1" rowspan="1" style="" align="center" valign="middle">1</td><td colspan="1" rowspan="1" style="" align="center" valign="middle"><p>North-South</p></td></tr></tbody></table></table-wrap></sec></sec><sec><title>3. Results and findings</title><p>According to <xref ref-type="bibr" rid="BIBR-1">(A.S.H.R.A.E., 2019)</xref>, the safe limit for CO<sub>2</sub> is 1000ppm. <xref ref-type="fig" rid="figure-1">Figure 3</xref> shows CO<sub>2</sub> levels in case study buildings. The red line is the guideline for CO<sub>2</sub> levels. The data below is an average of 24 hours which are numbered as day 1 to day 37, and on the y-axis, the levels of CO<sub>2</sub> are mentioned in terms of parts per million(ppm). The detailed analysis of CO<sub>2</sub> readings across the CSBs over 37 days reveals distinct patterns in IAQ. Flat C consistently maintained CO<sub>2</sub> levels below the ASHRAE guideline limit of 1000 ppm, indicating effective ventilation or lower occupancy levels and ensuring satisfactory IAQ. Flat G and F exhibited fluctuations in CO<sub><sup>2</sup></sub> levels, with occasional spikes, but most readings in Flat F were consistently above the guideline limit, suggesting significant challenges in ventilation or occupancy control. Flats B and E also displayed occasional exceedances of the guideline limit, indicating potential issues in ventilation or occupancy management. Flat D exhibited minor spikes during the initial days but was under the limit on most days after that. These flats experienced fluctuations in CO<sub>2</sub> levels, with occasional spikes possibly attributed to increased occupancy or limited ventilation. In contrast, Flat A consistently surpassed the guideline limit, indicating significant ventilation or occupancy issues requiring urgent intervention. Its persistently elevated CO<sub>2</sub> concentrations underscore the need for targeted measures to improve ventilation and reduce occupancy levels, ensuring a healthy indoor environment for occupants.</p><fig id="figure-1" ignoredToc=""><label>Figure 3</label><caption><p>Daily average readings of CO2  levels (Source: The authors)</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/47-57/1192/4738" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig><sec><title>3.2. CO<sub>2</sub> levels</title><p>Carbon monoxide is one of the most harmful pollutants <xref ref-type="bibr" rid="BIBR-23">(United States Environmental Protection Agency, 2023)</xref>. Higher concentration of CO is directly linked with high health risks. Many studies have shown that if CO levels rise too high in a room with no ventilation can result in fatal or even death. According to WHO, 2021, the safe limit for CO is 6 ppm which is an average of 24 hours. <xref ref-type="fig" rid="figure-3">Figure 4</xref> shows CO levels in CSBs, where the red line is the acceptable guideline for CO levels.</p><p>The findings reveal dangerously high CO pollution permeating Flats B, E, D, and A – facing extended durations exceeding 20 ppm daily averages by 3-20 times the safe limit. Specifically, Flat A suffered from sustained CO levels between 30-96 ppm from November 27th to December 14th. Additionally, extreme spikes reached up to 172 ppm on December 16th, indicating acute toxicity threats. In contrast, Flats C, G, and F only demonstrated occasional CO spikes above limits before recovering to alignment.</p><fig id="figure-3" ignoredToc=""><label>Figure 4</label><caption><p>Daily average readings of CO levels (Source: The authors)</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/47-57/1192/4739" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig></sec><sec><title>3.3. TVOC levels</title><p>TVOC are a group of chemicals that can be released into the air from various sources, including cleaning products, paints, and building materials. High levels of TVOC in indoor environments can lead to negative health effects, such as eye irritation, headaches, and respiratory problems. Therefore, it is important to monitor the TVOC levels in indoor spaces to ensure occupant safety and comfort. According to CIBSE, the recommended limit for TVOC is 80 ppb. In <xref ref-type="fig" rid="figure-4">Figure 5</xref>, the data displays TVOC levels in the CSBs over 37 days. The red line represents the recommended guideline limit.</p><p>The research findings show that all flats experienced recurring spikes above 80 ppb, often reaching alarming levels up to 10-20 times the limit, requiring closer inspection. Specifically, Flat C had periodic elevations ranging from 500-4000 ppb, including an extreme spike hitting 2019 ppb. Similarly, Flat D showed consistent ranges of 500-1500 ppb with spikes up to 2019 ppb. Even more critically, Flats F, B, and A had numerous TVOC measurements between 1000-5000 ppb. Flat F had a maximum of 4610 ppb at one point and Flat A reached 4860 ppb, representing extremely dangerous indoor pollution levels from volatile organic compounds.</p><fig id="figure-4" ignoredToc=""><label>Figure 5</label><caption><p>Daily average readings of TVOC levels (Source: The authors)</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/47-57/1192/4740" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig></sec><sec><title>3.4. PM<sub>10</sub> levels</title><p>PM<sub>10</sub> is a common air pollutant that can have harmful effects on human health. To address this issue, <xref ref-type="bibr" rid="BIBR-26">(W.H.O., 2021)</xref> has set a guideline for PM<sub>10</sub> levels on a 24-hour average of 45ug/m<sup>3</sup>. Any PM level that exceeds this limit within 24 hours is considered poor air quality. In <xref ref-type="fig" rid="figure-5">Figure 6</xref>, we can see a comparison of PM<sub>10</sub> levels in various CSBs. The red line represents the guideline for PM<sub>10</sub> levels. After analyzing the PM<sub>10</sub> data from all monitored flats, some units consistently exceeded the specified threshold of 45 μg/m<sup>3</sup>. However, Flats C, F, G, and B consistently maintained concentrations below this limit throughout the observation period, indicating good air quality. On the other hand, flats E, D, and A frequently recorded PM<sub>10</sub> levels exceeding the limit, indicating poorer air quality conditions in these units. Based on the provided data, we can conclude that Flats C, F, G, and B are committed to maintaining satisfactory IAQ levels for their residents by consistently adhering to the PM<sub>10</sub> limit. These flats stand out as examples of good practices in ensuring healthy living environments.</p><fig id="figure-5" ignoredToc=""><label>Figure 6</label><caption><p>Daily average readings of PM10 levels (Source: The authors)</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/47-57/1192/4741" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig></sec><sec><title>3.5. PM<sub>2.5</sub> levels</title><p>PM<sub>10</sub> and PM<sub>2.5</sub> are said to be co-related to each other but still, there is a vast difference in terms of their acceptable safe limit guideline inside the room. According to <xref ref-type="bibr" rid="BIBR-26">(W.H.O., 2021)</xref>, the guideline for PM<sub>2.5</sub> on a 24-hour average is 15ug/m<sup>3</sup>. In <xref ref-type="fig" rid="figure-6">Figure 7</xref>, PM<sub>2.5</sub> is compared in CSBs for 37 days. The red line is shown as a guideline for PM<sub>2.5</sub> levels. Upon meticulous examination of the PM<sub>2.5</sub> data, it's evident that none of the monitored flats surpassed the prescribed threshold of 15 μg/m<sup>3</sup> throughout the entire observation period. Even though some flats, such as Flat G and Flat A, sporadically recorded slightly elevated PM<sub>2.5</sub> levels on certain days, these instances were still well within the acceptable range and did not breach the established limit. Notably, Flat F consistently exhibited exceptionally low PM<sub>2.5</sub> concentrations, with values consistently below 1 μg/m<sup>3</sup>, showcasing excellent IAQ maintenance. Overall, all monitored flats maintained PM<sub>2.5</sub> levels within acceptable limits, indicating effective measures in place to ensure IAQ remained conducive to health and well-being throughout the monitoring period.</p><fig id="figure-6" ignoredToc=""><label>Figure 7</label><caption><p>Daily average readings of PM<sub>2.5</sub> levels (Source: The authors)</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/47-57/1192/4742" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig></sec><sec><title>3.6. Humidity levels</title><p>Humidity is the concentration of water vapor present in the air. It depends on the temperature and pressure present in the air. High humidity levels can create a risk for excess moisture and condensation that potentially leads to mold while low levels can rapidly spread viruses like cold and flu. Therefore, <xref ref-type="bibr" rid="BIBR-7">(C.I.B.S.E., 2021)</xref> has given a guideline for minimum and maximum limits of humidity levels present in the air which is 40% as the minimum safe limit and 70% as the maximum safe limit. In <xref ref-type="fig" rid="figure-7">Figure 8</xref>, the graph shows the humidity levels for all 7 CSBs throughout 37 days. The red line shows the guideline for relative humidity. The analysis of humidity levels across seven residential flats over 37 days reveals varied conditions experienced by occupants. Flat C generally maintained humidity levels within an acceptable range, fluctuating between 61.84% and 69.36%, consistently below the target limit of 70%. Similarly, Flat G exhibited relatively stable humidity levels ranging from 51.83% to 58.49%, ensuring comfortable living conditions throughout the observation period. In contrast, Flat F experienced diverse humidity levels between 55.09% and 70.97%, occasionally approaching or exceeding the target limit, particularly on Days 9, 10, 13, 17, and 25, yet overall conditions remained within an acceptable range for occupants. Flat B consistently maintained humidity levels below the target limit, fluctuating between 45.71% and 56.59%, ensuring comfortable living conditions for its residents. Likewise, Flat E showed relatively stable humidity levels ranging from 46.84% to 63.85%, remaining below the target limit throughout the observation period. Flat D recorded humidity levels between 52.49% and 66.78%, occasionally nearing the target limit but generally within an acceptable range. However, in Flat A, humidity levels fluctuated between 61.24% and 73.47%, occasionally exceeding the target limit, particularly on Days 29 and 37, potentially bordering on discomfort during peak periods. Despite fluctuations, most flats maintained acceptable humidity levels, with Flat A potentially requiring further monitoring and adjustments to ensure consistent comfort levels.</p><fig id="figure-7" ignoredToc=""><label>Figure 8</label><caption><p>Daily average readings of Humidity levels (Source: The authors)</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/47-57/1192/4743" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig></sec><sec><title>3.7. Temperature</title><p>The guideline levels for temperature are different in summer and winter. Here considering winter, the guideline for temperature is 22-23°C for living room. Temperature is important as this determines the thermal comfort of a room. Occupant behavior plays an important role in measuring indoor temperature as it is directly related to the usage of heating devices in a room. Here in <xref ref-type="fig" rid="figure-8">Figure 9</xref>, the temperature for 7 CSBs is shown in 24-hour average data. In considering the guideline for temperature, it is equally important to consider minimum and maximum limits. Therefore, the dark red line in <xref ref-type="fig" rid="figure-7">Figure 8</xref> shows the maximum guideline and the light red line shows the minimum guideline for temperature dew point. The detailed analysis of temperature readings across seven case study buildings over 37 days reveals varying levels of thermal comfort experienced by occupants. Flat C consistently maintained temperatures within the comfort range of 22 to 23 °C throughout the observation period, with occasional fluctuations but overall satisfactory conditions. Similarly, Flat G also exhibited mostly stable conditions within the comfort range, although minor deviations occurred on Day 6. Fluctuations in temperature readings were observed in Flat F, with frequent exceedances of the upper limit of the comfort range, particularly evident on Days 1, 3, 6, 7, 11, 12, 19, and 20, indicating potential discomfort due to warmer conditions. In contrast, Flat B displayed relatively stable conditions within the comfort range, with occasional deviations such as on Day 30. Flat E also maintained conditions within the comfort range for the most part, with minor fluctuations observed on Days 6 and 30. Similarly, Flat D generally experienced satisfactory thermal comfort levels, although slight deviations were noted on Day 6. However, Flat A consistently recorded temperatures below the lower limit of the comfort range, notably on Days 30 and 31, indicating potential discomfort due to cooler temperatures. Despite occasional deviations in some flats, most occupants likely experienced acceptable thermal comfort levels, with deviations in Flat F and Flat A warranting further investigation into factors such as insulation and heating/cooling systems to ensure consistent comfort across all flats.</p><fig id="figure-8" ignoredToc=""><label>Figure 9</label><caption><p>Daily average readings of Temperature levels (Source: The authors)</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/47-57/1192/4744" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig></sec></sec><sec><title>4. Discussion and conclusion</title><p>The investigation into the IAQ of seven residential flats has unveiled elevated levels of pollutants, posing potential health risks to the occupants. The findings from this study present a disconcerting scenario, with each residential unit exhibiting varying degrees of IAQ deficiencies that warrant immediate intervention and remediation strategies. Alarmingly, none of the monitored flats managed to maintain acceptable levels across all key pollutants, including CO2, CO, TVOCs, PM10 and PM<sub>2.5</sub>, and humidity and temperature deviations.</p><p>Flat A emerged as a critical concern, exhibiting multiple IAQ issues that require immediate attention. The persistent elevation of CO<sub>2</sub> levels above the guideline limit indicates inadequate ventilation. Moreover, the dangerously high CO concentrations, ranging from 30-96 ppm with extreme spikes up to 172 ppm, pose severe health risks. The alarming TVOC level of 4860 ppb, up to 20 times the recommended limit, could be attributed to the occupant's activities like candle burning, air freshener use, and vaping. Furthermore, PM<sub>10</sub> levels frequently exceeded the guideline, potentially linked to vaping. Flat A's occupant behavior, such as not using extractor fans in the kitchen and bathroom, and the potential for poor insulation or heating systems, as evident from temperature readings below the lower comfort limit, exacerbated the air quality concerns. Flat D experienced significant challenges in maintaining acceptable IAQ levels. High CO levels, exceeding the safe limit several times, could be attributed to insufficient background ventilation, a broken extractor fan in the kitchen, and the occupants' reluctance to use bathroom fans due to energy consumption concerns. PM<sub>10</sub> levels also frequently surpassed the guideline, potentially due to the same factors. The open kitchen layout, combined with three occupants, may have contributed to the elevated pollutant levels. Addressing the ventilation issues and encouraging the use of extractor fans is crucial for improving air quality in this flat. IAQ in this flat B was compromised by dangerously high CO levels, exceeding the safe limit. The locked kitchen window, preventing proper ventilation, could be a significant contributing factor. As this flat houses a vulnerable elderly occupant, swift action to improve ventilation and mitigate CO exposure is essential to safeguard their health and well-being. While most parameters of Flat E were within acceptable limits, this flat experienced frequent exceedances of the PM<sub>10</sub> guideline, indicating poorer air quality conditions. The presence of three occupants, including an elderly individual, underscores the importance of addressing the PM<sub>10</sub> issue through ventilation improvements and source control measures. Flat F exhibited several air quality concerns, potentially related to recent renovations, including new kitchen tiles and fresh painting, combined with a higher occupancy of four individuals, including a pregnant woman. TVOC levels reached up to 4610 ppb, well above the recommended limits, posing potential health risks, especially for vulnerable occupants. Additionally, temperature and humidity levels frequently exceeded the recommended ranges, indicating a need for improved climate control and ventilation strategies. Among the monitored flats, Flat G demonstrated relatively acceptable IAQ, maintaining TVOC levels below the recommended limit and stable humidity levels within an acceptable range. However, occasional CO spikes above the safe limit suggest the need for further monitoring and potential ventilation improvements. Flat C consistently maintained CO<sub>2</sub> levels below the guideline limit, indicating effective ventilation or lower occupancy levels. However, periodic TVOC spikes, with levels reaching up to 4000 ppb, suggest the presence of intermittent sources that require investigation and mitigation strategies.</p><p>Weather conditions played a pivotal role in the fluctuating levels of pollutants. Peaks in pollutant levels were often recorded during colder days when occupants likely kept windows closed, reducing ventilation and trapping pollutants indoors. Conversely, on milder days, lower pollutant levels were observed, correlating with increased natural ventilation. This was also observed during the site visits when occupants opened the windows during milder days and in some cases for thermal comfort reasons. There were also direct links between wind speed and concentration of IAPs particularly for TVOCs, and CO<sub>2</sub>, however, the assessments were not conclusive for other IAPs. <xref ref-type="fig" rid="figure-9">Figure 10</xref>, shows an example of the correlation between some IAPs (CO<sub><sup>2</sup></sub> ) and wind speed in the CSBs.</p><fig id="figure-9" ignoredToc=""><label>Figure 10</label><caption><p>Correlation between the external temperature, wind speed, and IAPs (Source: The authors)</p></caption><graphic xlink:href="https://press.ierek.com/index.php/ESSD/article/download/47-57/1192/4745" mimetype="image" mime-subtype="png"><alt-text>Image</alt-text></graphic></fig><p>The analysis highlights the varying degrees of IAQ challenges faced by each residential unit, influenced by factors such as occupancy patterns, ventilation practices, and potential pollutant sources. Comprehensive remediation efforts tailored to the specific circumstances of each flat are crucial to safeguard occupant health and ensure a comfortable living environment. These efforts may include ventilation system upgrades, source control measures, occupancy management strategies, and collaborative efforts among building owners, occupants, and relevant authorities to implement best practices, regular monitoring, and education. Further research is required to assess the correlation between indoor/outdoor air pollutants, the effects of occupant behavior on IAQ, as well as possible application of fuzzy logic techniques <xref ref-type="bibr" rid="BIBR-25">(Versaci et al., 2022)</xref> on data analysis.</p></sec><sec><title>Acknowledgment</title><p>This document is an output from a research project, Healthy Energy Efficient Dwellings (HEED), funded by the UK Research and Innovation (UKRI), Medical Research Council (MRC) [Grant number: MR/Y503186/1]. Also, the authors would like to thank the Newham Council, Hyde Housing Association, and iOpt Limited for supporting the project and providing access to the properties.</p><p>The abstract of this paper was presented at the Environmental Design, Material Science, and Engineering Technologies (EDMSET) Conference -1st Edition which was held on the 22nd -24th of April 2024.</p><sec><title>Funding declaration</title><p>This research was funded by the UK Research and Innovation (UKRI), Medical Research Council (MRC) [Grant number: MR/Y503186/1].</p></sec><sec><title>Ethics approval</title><p>The authors have received ethics approval from the ethics committee of the University of East London, for the interviews and surveys that were conducted by the authors.</p></sec><sec><title>Conflict of interest</title><p>The authors declare that there is no competing interest.</p></sec></sec></body><back><ref-list><title>References</title><ref id="BIBR-1"><element-citation publication-type=""><article-title>STANDARDS ADDENDA</article-title><person-group person-group-type="author"><name name-style="given-only"><given-names>A.S.H.R.A.E.</given-names></name></person-group><year>2019</year></element-citation></ref><ref id="BIBR-2"><element-citation publication-type="article-journal"><article-title>A review of critical residential buildings parameters and activities when investigating indoor air quality and pollutants</article-title><source>Indoor air</source><volume>32</volume><issue>11</issue><person-group person-group-type="author"><name><surname>Baeza_Romero</surname><given-names>M.T.</given-names></name><name><surname>Dudzinska</surname><given-names>M.R.</given-names></name><name><surname>Amouei Torkmahalleh</surname><given-names>M.</given-names></name><name><surname>Barros</surname><given-names>N.</given-names></name><name><surname>Coggins</surname><given-names>A.M.</given-names></name><name><surname>Ruzgar</surname><given-names>D.G.</given-names></name><name><surname>Kildsgaard</surname><given-names>I.</given-names></name><name><surname>Naseri</surname><given-names>M.</given-names></name><name><surname>Rong</surname><given-names>L.</given-names></name><name><surname>Saffell</surname><given-names>J.</given-names></name><name><surname>Scutaru</surname><given-names>A.M.</given-names></name></person-group><year>2022</year><page-range>13144</page-range></element-citation></ref><ref id="BIBR-3"><element-citation publication-type="article-journal"><article-title>Poor housing quality: Prevalence and health effects</article-title><source>Journal of prevention &amp; intervention in the community</source><volume>44</volume><issue>4</issue><person-group person-group-type="author"><name><surname>Baker</surname><given-names>E.</given-names></name><name><surname>Lester</surname><given-names>L.H.</given-names></name><name><surname>Bentley</surname><given-names>R.</given-names></name><name><surname>Beer</surname><given-names>A.</given-names></name></person-group><year>2016</year><fpage>219</fpage><lpage>232</lpage><page-range>219-232</page-range><pub-id pub-id-type="doi">10.1080/10852352.2016.1197714</pub-id><ext-link xlink:href="10.1080/10852352.2016.1197714" ext-link-type="doi" xlink:title="Poor housing quality: Prevalence and health effects">10.1080/10852352.2016.1197714</ext-link></element-citation></ref><ref id="BIBR-4"><element-citation publication-type="article-journal"><article-title>Wintertime indoor temperatures in social housing dwellings in England and the impact of dwelling characteristics</article-title><source>Energy and Buildings</source><volume>238</volume><person-group person-group-type="author"><name><surname>Beizaee</surname><given-names>A.</given-names></name><name><surname>Morey</surname><given-names>J.</given-names></name><name><surname>Badiei</surname><given-names>A.</given-names></name></person-group><year>2021</year><page-range>110837</page-range></element-citation></ref><ref id="BIBR-5"><element-citation publication-type="article-journal"><article-title>Towards sustainable, energy-efficient and healthy ventilation strategies in buildings: A review</article-title><source>Renewable and Sustainable Energy Reviews</source><volume>59</volume><person-group person-group-type="author"><name><surname>Chenari</surname><given-names>B.</given-names></name><name><surname>Dias Carrilho</surname><given-names>J.</given-names></name><name><surname>Silva</surname><given-names>M.</given-names></name></person-group><year>2016</year><fpage>1426</fpage><lpage>1447</lpage><page-range>1426-1447</page-range><pub-id pub-id-type="doi">10.1016/j.rser.2016.01.074</pub-id><ext-link xlink:href="10.1016/j.rser.2016.01.074" ext-link-type="doi" xlink:title="Towards sustainable, energy-efficient and healthy ventilation strategies in buildings: A review">10.1016/j.rser.2016.01.074</ext-link></element-citation></ref><ref id="BIBR-6"><element-citation publication-type="article-journal"><article-title>Chartered Institution of Building Services Engineers (CIBSE) TM40 - 2020 Guide – Indoor air quality comparisons</article-title><source>Scottish Government</source><person-group person-group-type="author"><name><surname>TM40</surname><given-names>C.I.B.S.E.</given-names></name></person-group><year>2020</year></element-citation></ref><ref id="BIBR-7"><element-citation publication-type="book"><article-title>Chartered Institution of Building Services Engineers (CIBSE) Guide A: Environmental Design</article-title><person-group person-group-type="author"><name name-style="given-only"><given-names>C.I.B.S.E.</given-names></name></person-group><year>2021</year><publisher-name>CIBSE Publications</publisher-name></element-citation></ref><ref id="BIBR-8"><element-citation publication-type=""><article-title>Indoor air quality in new and renovated low-income apartments with mechanical ventilation and natural gas cooking in California</article-title><person-group person-group-type="author"><name><surname>H.</surname><given-names>Daphne</given-names></name><name><surname>Mandin.</surname><given-names>Hermione</given-names></name><name><surname>W.R.</surname><given-names>Chan</given-names></name><name><surname>Walker.</surname><given-names>Cohn</given-names></name><name><surname>Y.S.</surname><given-names>Kim</given-names></name><name><surname>M</surname><given-names>Cheng</given-names></name></person-group><year>2021</year></element-citation></ref><ref id="BIBR-9"><element-citation publication-type="article-journal"><article-title>Indoor air quality, ventilation, and respiratory health in elderly residents living in nursing homes in Europe</article-title><source>European Journal of Public Health</source><person-group person-group-type="author"><name><surname>Hanssen</surname><given-names>S.O.</given-names></name><name><surname>Aasvang</surname><given-names>G.M.</given-names></name><name><surname>Samuelsen</surname><given-names>M.</given-names></name></person-group><year>2018</year></element-citation></ref><ref id="BIBR-10"><element-citation publication-type="article-journal"><article-title>Source specific exposure and risk assessment for indoor aerosols</article-title><source>Sci. Total Environ</source><volume>668</volume><person-group person-group-type="author"><name><surname>Koivisto</surname><given-names>A.J.</given-names></name><name><surname>Kling</surname><given-names>K.I.</given-names></name><name><surname>Hänninen</surname><given-names>O.</given-names></name><name><surname>Jayjock</surname><given-names>M.</given-names></name><name><surname>Löndahl</surname><given-names>J.</given-names></name><name><surname>Wierzbicka</surname><given-names>A.</given-names></name><name><surname>Fonseca</surname><given-names>A.S.</given-names></name><name><surname>Uhrbrand</surname><given-names>K.</given-names></name><name><surname>Boor</surname><given-names>B.E.</given-names></name><name><surname>Jiménez</surname><given-names>A.S.</given-names></name><etal/></person-group><year>2019</year><fpage>13</fpage><lpage>24</lpage><page-range>13-24</page-range></element-citation></ref><ref id="BIBR-11"><element-citation publication-type="article-journal"><article-title>Respiratory health effects of air pollution: Update on biomass smoke and traffic pollution</article-title><source>Journal of Allergy and Clinical Immunology</source><volume>129</volume><issue>1</issue><person-group person-group-type="author"><name><surname>Laumbach</surname><given-names>R.J.</given-names></name><name><surname>Kipen</surname><given-names>H.M.</given-names></name></person-group><year>2012</year><fpage>3</fpage><lpage>11</lpage><page-range>3-11</page-range><pub-id pub-id-type="doi">10.1016/j.jaci.2011.11.021</pub-id><ext-link xlink:href="10.1016/j.jaci.2011.11.021" ext-link-type="doi" xlink:title="Respiratory health effects of air pollution: Update on biomass smoke and traffic pollution">10.1016/j.jaci.2011.11.021</ext-link></element-citation></ref><ref id="BIBR-12"><element-citation publication-type="chapter"><article-title>Indoor Environmental Quality Performance</article-title><source>Retrieved from U.S GREEN BUILDING COUNCIL: USGBC | U.S</source><person-group person-group-type="author"><name name-style="given-only"><given-names>L.E.E.D.</given-names></name></person-group><year>2023</year><publisher-name>Green Building Council</publisher-name></element-citation></ref><ref id="BIBR-13"><element-citation publication-type="article-journal"><article-title>Indoor Air Quality in Buildings: A Comprehensive Review on the Factors Influencing Air Pollution in Residential and Commercial Structure</article-title><source>International journal of environmental research and public health</source><volume>18</volume><issue>6</issue><person-group person-group-type="author"><name><surname>Mannan</surname><given-names>M.</given-names></name><name><surname>Al-Ghamdi</surname><given-names>S.G.</given-names></name></person-group><year>2021</year><page-range>3276</page-range><pub-id pub-id-type="doi">10.3390/ijerph18063276</pub-id><ext-link xlink:href="10.3390/ijerph18063276" ext-link-type="doi" xlink:title="Indoor Air Quality in Buildings: A Comprehensive Review on the Factors Influencing Air Pollution in Residential and Commercial Structure">10.3390/ijerph18063276</ext-link></element-citation></ref><ref id="BIBR-14"><element-citation publication-type="article-journal"><article-title>Indoor air quality of everyday use spaces dedicated to specific purposes—A review</article-title><source>Environ. Sci. Pollut. Res</source><volume>25</volume><person-group person-group-type="author"><name><surname>Marć</surname><given-names>M.</given-names></name><name><surname>Śmiełowska</surname><given-names>M.</given-names></name><name><surname>Namieśnik</surname><given-names>J.</given-names></name><name><surname>Zabiegała</surname><given-names>B.</given-names></name></person-group><year>2018</year><fpage>2065</fpage><lpage>2082</lpage><page-range>2065-2082</page-range></element-citation></ref><ref id="BIBR-15"><element-citation publication-type=""><article-title>Contribution of solid fuel, gas combustion, or tobacco smoke to indoor air pollutant concentrations in Irish and Scottish homes</article-title><person-group person-group-type="author"><name><surname>T.</surname><given-names>Margaret</given-names></name><name><surname>Pleil.</surname><given-names>Biros</given-names></name><name><surname>S.</surname><given-names>Semple</given-names></name><name><surname>C.</surname><given-names>Garden</given-names></name><name><surname>M.</surname><given-names>Coggins</given-names></name><name><surname>K.S.</surname><given-names>Galea</given-names></name><name><surname>P.</surname><given-names>Whelan</given-names></name><name><surname>H.</surname><given-names>Cowie</given-names></name><name><surname>A.</surname><given-names>Sánchez-Jiménez</given-names></name><name><surname>P.S.</surname><given-names>Thorne</given-names></name><name><surname>J.F.</surname><given-names>Hurley</given-names></name><name><surname>J.G</surname><given-names>Ayres</given-names></name></person-group><year>2020</year></element-citation></ref><ref id="BIBR-16"><element-citation publication-type="chapter"><article-title>Urban Overheating and Impact on Health: An Introduction</article-title><source>Urban Overheating: Heat Mitigation and the Impact on Health</source><person-group person-group-type="author"><name><surname>Mavrogianni</surname><given-names>A.</given-names></name><name><surname>Tsoulou</surname><given-names>I.</given-names></name><name><surname>Heaviside</surname><given-names>C.</given-names></name><name><surname>Oikonomou</surname><given-names>E.</given-names></name><name><surname>Petrou</surname><given-names>G.</given-names></name><name><surname>Symonds</surname><given-names>P.</given-names></name><name><surname>Davies</surname><given-names>M.</given-names></name><name><surname>Taylor</surname><given-names>J.</given-names></name><name><surname>Milojevic</surname><given-names>A.</given-names></name><name><surname>Wilkinson</surname><given-names>P.</given-names></name></person-group><year>2022</year><fpage>1</fpage><lpage>20</lpage><page-range>1-20</page-range><publisher-name>Advances in Sustainability Science and Technology). Springer</publisher-name><pub-id pub-id-type="doi">10.1007/978-981-19-4707-0_1</pub-id><ext-link xlink:href="10.1007/978-981-19-4707-0_1" ext-link-type="doi" xlink:title="Urban Overheating and Impact on Health: An Introduction">10.1007/978-981-19-4707-0_1</ext-link></element-citation></ref><ref id="BIBR-17"><element-citation publication-type="article-journal"><article-title>Association of classroom ventilation with reduced illness absence: A prospective study in California elementary schools</article-title><source>Indoor Air</source><volume>26</volume><issue>5</issue><person-group person-group-type="author"><name><surname>Mendell</surname><given-names>M.J.</given-names></name><name><surname>Eliseeva</surname><given-names>E.A.</given-names></name><name><surname>Spears</surname><given-names>M.</given-names></name><name><surname>Fisk</surname><given-names>W.J.</given-names></name><name><surname>Apte</surname><given-names>M.G.</given-names></name></person-group><year>2016</year><fpage>697</fpage><lpage>710</lpage><page-range>697-710</page-range></element-citation></ref><ref id="BIBR-18"><element-citation publication-type=""><article-title>National Institute of Environmental Health Sciences</article-title><year>2024</year><ext-link xlink:href="https://www.niehs.nih.gov/research/supported/translational/justice" ext-link-type="uri" xlink:title="National Institute of Environmental Health Sciences">National Institute of Environmental Health Sciences</ext-link></element-citation></ref><ref id="BIBR-19"><element-citation publication-type="article-journal"><article-title>Investigation of indoor air quality and the identification of influential factors at primary schools in the north of china</article-title><source>Sustainability</source><volume>9</volume><person-group person-group-type="author"><name><surname>Peng</surname><given-names>Z.</given-names></name><name><surname>Deng</surname><given-names>W.</given-names></name><name><surname>Tenorio</surname><given-names>R.</given-names></name></person-group><year>2017</year><page-range>1180</page-range></element-citation></ref><ref id="BIBR-20"><element-citation publication-type="article-journal"><article-title>Statistical analysis of parameters influencing the relationship between outdoor and indoor air quality in schools</article-title><source>Atmos. Environ</source><volume>39</volume><person-group person-group-type="author"><name><surname>Poupard</surname><given-names>O.</given-names></name><name><surname>Blondeau</surname><given-names>P.</given-names></name><name><surname>Iordache</surname><given-names>V.</given-names></name><name><surname>Allard</surname><given-names>A.</given-names></name></person-group><year>2005</year><fpage>2071</fpage><lpage>2080</lpage><page-range>2071-2080</page-range></element-citation></ref><ref id="BIBR-21"><element-citation publication-type=""><article-title>Guide to Arc Re-Entry v1.1</article-title><person-group person-group-type="author"><name><surname>Pyke</surname><given-names>C.R.</given-names></name></person-group><year>2020</year><page-range>24</page-range><publisher-loc>ArcSkoru, LLC, Washington, DC</publisher-loc></element-citation></ref><ref id="BIBR-22"><element-citation publication-type="article-journal"><article-title>Indoor Air Pollution, Related Human Diseases, and Recent Trends in the Control and Improvement of Indoor Air Quality</article-title><source>International Journal of Environmental Research and Public Health</source><volume>17</volume><issue>8</issue><person-group person-group-type="author"><name><surname>Tran</surname><given-names>V.V.</given-names></name><name><surname>Park</surname><given-names>D.</given-names></name><name><surname>Lee</surname><given-names>Y.</given-names></name></person-group><year>2020</year><page-range>2927</page-range></element-citation></ref><ref id="BIBR-23"><element-citation publication-type=""><article-title>United States Environmental Protection Agency</article-title><year>2023</year><ext-link xlink:href="https://www.epa.gov/co-pollution" ext-link-type="uri" xlink:title="United States Environmental Protection Agency">United States Environmental Protection Agency</ext-link></element-citation></ref><ref id="BIBR-24"><element-citation publication-type="article-journal"><article-title>Impact of climate change on the domestic indoor environment and associated health risks in the UK</article-title><source>Environment International</source><volume>85</volume><person-group person-group-type="author"><name><surname>Vardoulakis</surname><given-names>S.</given-names></name><name><surname>Dimitroulopoulou</surname><given-names>C.</given-names></name><name><surname>Thornes</surname><given-names>J.</given-names></name><name><surname>Lai</surname><given-names>K.M.</given-names></name><name><surname>Taylor</surname><given-names>J.</given-names></name><name><surname>Myers</surname><given-names>I.</given-names></name><name><surname>Heaviside</surname><given-names>C.</given-names></name><name><surname>Mavrogianni</surname><given-names>A.</given-names></name><name><surname>Shrubsole</surname><given-names>C.</given-names></name><name><surname>Chalabi</surname><given-names>Z.</given-names></name><name><surname>Davies</surname><given-names>M.</given-names></name></person-group><year>2015</year><fpage>299</fpage><lpage>313</lpage><page-range>299-313</page-range><pub-id pub-id-type="doi">10.1016/j.envint.2015.09.010</pub-id><ext-link xlink:href="10.1016/j.envint.2015.09.010" ext-link-type="doi" xlink:title="Impact of climate change on the domestic indoor environment and associated health risks in the UK">10.1016/j.envint.2015.09.010</ext-link></element-citation></ref><ref id="BIBR-25"><element-citation publication-type=""><article-title>A Fuzzy Similarity-Based Approach to Classify Numerically Simulated and Experimentally Detected Carbon Fiber-Reinforced Polymer Plate Defects</article-title><volume>22</volume><issue>11</issue><person-group person-group-type="author"><name><surname>Versaci</surname><given-names>M.</given-names></name><name><surname>Angiulli</surname><given-names>G.</given-names></name><name><surname>Crucitti</surname><given-names>P.</given-names></name><name><surname>Carlo</surname><given-names>D.</given-names></name><name><surname>Laganà</surname><given-names>F.</given-names></name><name><surname>Pellicanò</surname><given-names>D.</given-names></name><name><surname>Palumbo</surname><given-names>A.</given-names></name></person-group><year>2022</year><page-range>4232</page-range><publisher-loc>Sensors (Basel, Switzerland</publisher-loc><pub-id pub-id-type="doi">10.3390/s22114232</pub-id><ext-link xlink:href="10.3390/s22114232" ext-link-type="doi" xlink:title="A Fuzzy Similarity-Based Approach to Classify Numerically Simulated and Experimentally Detected Carbon Fiber-Reinforced Polymer Plate Defects">10.3390/s22114232</ext-link></element-citation></ref><ref id="BIBR-26"><element-citation publication-type=""><article-title>World Health Organisation Global Air Quality Guidelines</article-title><person-group person-group-type="author"><name name-style="given-only"><given-names>W.H.O.</given-names></name></person-group><year>2021</year></element-citation></ref><ref id="BIBR-27"><element-citation publication-type="article-journal"><article-title>Volatile organic compounds (VOCs) in indoor air: An overview</article-title><source>Indoor Air</source><volume>28</volume><issue>2</issue><person-group person-group-type="author"><name><surname>Wolkoff</surname><given-names>P.</given-names></name><name><surname>Schneider</surname><given-names>T.</given-names></name><name><surname>Kildesø</surname><given-names>J.</given-names></name><name><surname>Degerth</surname><given-names>R.</given-names></name></person-group><year>2018</year><fpage>160</fpage><lpage>170</lpage><page-range>160-170</page-range></element-citation></ref><ref id="BIBR-28"><element-citation publication-type="article-journal"><article-title>A comprehensive review of indoor air pollutants: sources, effects, and mitigation strategies</article-title><source>Plant Archives</source><volume>23</volume><issue>2</issue><person-group person-group-type="author"><name><surname>Yadav</surname><given-names>S.</given-names></name><name><surname>Kumar</surname><given-names>N.</given-names></name><name><surname>Kumar</surname><given-names>V.</given-names></name><name><surname>Jha</surname><given-names>V.</given-names></name><name><surname>Chhikara</surname><given-names>S.K.</given-names></name></person-group><year>2023</year></element-citation></ref><ref id="BIBR-29"><element-citation publication-type="article-journal"><article-title>Enabling efficient WiFi-based occupant behaviour recognition using insufficient samples</article-title><source>Building and Environment</source><volume>212</volume><person-group person-group-type="author"><name><surname>Zhou</surname><given-names>Q.</given-names></name><name><surname>Yang</surname><given-names>Q.</given-names></name><name><surname>Xing</surname><given-names>J.</given-names></name></person-group><year>2022</year><page-range>108806</page-range></element-citation></ref></ref-list></back></article>
